Open-pit or underground mine
Changing terrain, benches, and active working areas require updates to the RF model.
Mining and open-pit operations
Connectivity and IT infrastructure for open-pit mines, underground mines, and mining enterprises, from field assessment to network operation.
Field units and equipment → radio network → backhaul → applications → monitoring
Connectum delivers the network infrastructure: connectivity for equipment and field units, data transport, integration, and monitoring. Dispatch, RTLS, and autonomous control platforms connect as separate systems provided by the customer or partners.
Types of sites and roles
The architecture depends on terrain, elevations, equipment routes, and the availability of supporting infrastructure.
Changing terrain, benches, and active working areas require updates to the RF model.
Metal, equipment and production facilities form a complex RF environment.
Outdoor areas, buildings, and process installations are connected within a single managed environment.
Pumping, power and control points require data transport and monitoring.
Onboard terminals and controllers are tested along actual routes and with the operating application.
Processes and requirements
Infrastructure does not replace application systems, but determines the availability of data and control loops.
| Process | What depends on the infrastructure | The main risk | What we document in the project |
|---|---|---|---|
| Telemetry and dispatching | Delivery of data from equipment and field units | Losses and delays on the route | Coverage, availability, delay and control points |
| Mobile equipment | Stable application session in motion | Disconnections when changing coverage areas or radio paths | Routes, client, antennas and criteria for switching between access points |
| Industrial video | Stream transport to analytics and archive | Insufficient bandwidth and uncontrolled uplink traffic | Traffic profile, priorities and reserve |
| Staff communications | Access in working and remote areas | Shadow zones and general segment overload | Areas, Roles, Segmentation and Priorities |
| Development of mining operations | Relocate and add units while retaining network control | Architecture ceases to correspond to the site | Extension rules, monitoring and re-measurement |
Customer and partner software platforms remain separate areas of responsibility. Connectum delivers coordinated network transport and integration.
Priority workflows
The result criterion is set at the application and process level, not just the signal level.
Onboard unit → radio access → backhaul → dispatch system. We check routes, latency, and packet loss.
The architecture accommodates relocation and addition of field units while checking for new coverage gaps.
Wireless bridges or mesh links connect areas without available fiber. Redundancy and bandwidth are selected for the task.
An audit distinguishes RF, client device, configuration, and backhaul problems before equipment is purchased.
Reference architecture
We adapt the reference architecture after assessing the site and documenting application requirements.
Equipment, sensors, cameras, terminals and industrial controllers.
Industrial access points, mesh nodes and client devices on equipment.
Wireless bridges, mesh backhaul, fiber-optic links, or a hybrid design.
Segmentation, policies, controllers and monitoring.
Dispatching, telemetry, video and other systems of the customer or partner.
Monitoring, redundancy, change procedures, and repeat measurements.
Deployment program
We adapt the scope and checkpoints to the site, access arrangements, and permitted work windows.
Plans, routes of equipment, applications, access restrictions and the current scheme.
Field measurements, radio model and prioritization of critical areas.
Validate the architecture and a client device workflow in a limited area.
Deployment to sites and acceptance according to the agreed program.
Documentation, monitoring, areas of responsibility and network development plan.
Project experience
Published projects show the experience of working with industrial networks in the field.
Operational framework
Redundancy levels and SLA terms are defined after classifying services and access requirements.
Check not only the presence of the second path, but also its capacity, RF environment and common points of failure.
We separate client classes, service environments and application flows according to the agreed model.
Relocating units and expanding operations require measurements, documentation updates, and configuration control.
Questions before the start
These answers help define requirements, scope, and the appropriate first project stage.
Yes, an industrial Wi‑Fi/mesh network can be used as a radio layer of an enterprise’s mobile operational network if the architecture, client nodes and application criteria are confirmed by inspection and testing.
No. The choice depends on the spectrum, coverage, client devices, mobility requirements, latency, capacity and operation. The architecture is often hybrid.
Connectum delivers the network infrastructure: connectivity for equipment and field units, data transport, integration, and monitoring. Dispatch, RTLS, and autonomous control platforms connect as separate systems provided by the customer or partners.
At the project stage, the expansion rules, locations for possible node transfer, control measurements and monitoring requirements are set.
Yes. The pilot is useful if it reproduces a critical route, application, client device and real RF environment conditions.
Start with a description of symptoms, diagrams, logs, and a field audit. Diagnosis helps avoid replacing equipment without establishing the cause.
Analysis of the site
Attach a site plan, equipment routes, a list of field units, and descriptions of critical applications. We will identify missing inputs and the appropriate first stage.
An engineer will review the project inputs before we respond.