Connectivity deteriorates in meeting rooms
With a high density of participants, delays, losses and the number of reconnections increase.
Managed Network for Business
We design and deploy corporate Wi‑Fi for employees, guests, contractors, and building services. We calculate coverage and capacity, separate access, and integrate authentication and monitoring. Acceptance testing covers meeting rooms, work areas, and high-density spaces using agreed applications and user roles.
Client devices → radio access → wired infrastructure → access and security → management
Enterprise Wi‑Fi is a managed local area network for business applications, employees, guests, contractors and building services. The Internet channel provides external access, and the WLAN project defines coverage, capacity, segmentation, authentication, security policies, monitoring and operating rules within the facility. The architecture depends on the density of users, applications, information security requirements and management model.
Signs that a solution is needed
The problem is visible not only by the signal level, but by the behavior of the video conferencing, cloud applications and users in different zones.
With a high density of participants, delays, losses and the number of reconnections increase.
There is no clear isolation, roles, access policies, and responsibilities between IT, information security, and service owners.
New tenants, floors and services are added manually and without a single configuration model.
Client events, RF channel utilization, equipment condition, and causes of degraded performance are not monitored.
Design factors
The layout, density and composition of applications must be considered together.
Open office areas, meeting rooms and waiting areas require a separate calculation of the capacity.
In the business center, tenants, management company, guests and services of the building are separated.
Video conferencing, telephony and cloud applications and virtual workplaces set requirements for delay and loss.
Authentication methods, roles, logs and integrations with corporate directories are checked.
Scenarios
Employees, meeting rooms, guest access and corporate applications.
Separation of tenants and shared services on a single managed infrastructure.
Workplaces, video conferencing and telephony with minimal dependence on wired access.
Temporary high density and separate guest connection rules.
Architecture
The reference architecture links radio access to wired infrastructure, authentication services, information security policies, monitoring and redundancy. The exact composition depends on the infrastructure and requirements of the customer.
Laptops, phones, video conferencing, corporate applications, guests and devices of the building.
Access points, channel plan, power management and high density calculation.
Switches, PoE, trunk lines, uplink and backup connections.
SSIDs, VLANs/VRFs within the agreed architecture, 802.1X, certificates, guest portals, and policies.
Local controller or cloud platform, configurations, logs and backups.
Host and client events, alerts, escalation and reporting.
Model of management
| Mechanism | What it does | What we check |
|---|---|---|
| Local management (on-premises) | The controller, the configurations and the agreed composition of the operational data are placed in the customer's environment. | Backup, updates, administrator access, log storage and team competence. |
| Cloud management (cloud-managed) | Centralizes the configuration and monitoring of one or more sites through the manufacturer’s service. | Security policies, transmitted data, licenses, management availability, roles, and service exit procedures. |
| Managed service | Part of the operation and monitoring is performed by an external team within agreed boundaries. | SLA, access to data and configurations, areas of responsibility, escalation and order changes. |
Stages of the project
Define the site, user roles, applications, density, information security requirements and result criteria.
We study plans, current WLAN, wired network, RF environment and location restrictions.
We calculate the coverage and capacity, form segmentation, access, transport, control and acceptance program.
We agree on the platform, licenses, versions, completeness and switching plan.
Deploy WLAN, integrate authentication, policies, monitoring and redundancy.
Check zones, load scenarios, applications, access roles and agreed failures.
Results
The exact composition of the project, configurations, protocols and operational materials is determined by the contract.
Acceptance
| Criterion | How to check | Where we document |
|---|---|---|
| Coverage and capacity | Measurements in work areas and test under the agreed load. | Heat maps and test protocol. |
| Business applications | Verification of video conferencing, voice and cloud services on typical clients. | A log of latency, packet loss, and session stability. |
| Access segmentation | Checking roles, segments and forbidden transitions. | Access matrix and test results. |
The schedule depends on floors and sites, room access, plan quality, wired network condition, user roles, directory and certificate integrations, pilot requirements, and switching windows for the existing WLAN.
Costs are determined by area and density, number of access points and network nodes, management licenses, redundancy requirements, switching and PoE upgrades, information security integrations, installation, commissioning and acceptance tests. Mandatory and additional parts are shown separately.
The SLA records supported sites and platforms, monitored events, incident priorities, response times, escalation procedures, change windows, backups and reporting format. Responsibility boundaries between the customer's IT team, information security, internet provider and Connectum are described separately.
Questions and answers
Internet connectivity provides external access. Corporate WLAN provides connectivity within the site, including coverage, capacity, segmentation, authentication, security, management, and monitoring. These require coordinated design and clear responsibilities. A faster internet link alone does not resolve interference, overloaded radio channels, or internal access policy errors.
Yes, with an agreed isolation model, property manager roles, addressing, access policies, performance requirements, and administration rules. The mechanism depends on the architecture and site security requirements. Acceptance testing verifies permitted and prohibited traffic paths, administrator roles, and each tenant’s access to its resources.
Guest access is isolated from corporate resources and has its own policies, limits, and logging. A separate SSID may form part of the design but does not provide isolation by itself: the complete traffic path and firewall rules must be checked. Authentication methods and logged data depend on site requirements and the agreed legal model.
Design considers concurrent devices, traffic profiles, client capabilities, available spectrum, and wired infrastructure. After deployment, testing covers signal strength and the performance of video conferencing, voice, and other agreed applications under representative load. Channel planning, placement, and transmit power account for neighboring areas and actual client devices.
Deployment is usually divided by floor, area, or work window. Parallel operation of old and new WLANs, switching order, and rollback are defined after reviewing the architecture, cabling, and business operating schedule. The agreed work plan records permitted interruptions, responsible parties, and checks after each switch.
The choice depends on security requirements, site count, data, licensing, internal expertise, and acceptable dependence on an external service. Before deciding, we compare redundancy, administrator access, updates, log storage, and service termination procedures. We also check which network functions remain available without management connectivity and how configurations are transferred when the operating model changes.
Provide plans, employee and guest numbers, peak device density by area, applications, critical client models, security requirements, directories and certificates, existing access points and controllers, switching, PoE, and internet links. Problem areas, access schedules, planned changes, and permitted switching windows are also useful.
Before design, we agree on areas, applications, load scenarios, and access roles. After deployment, we test coverage, capacity, video conferencing and other applications, segmentation, monitoring, and redundancy scenarios. The agreed SLA defines ongoing support, monitored events, responsibilities, escalation, and response targets. Support arrangements are specific to each site.
The next step
Send plans, user and guest numbers, peak density, applications, security requirements, and existing network details. The Connectum team will review the inputs and suggest a survey, design, or audit as the next stage.
Material prepared by Connectum technical team · updated: August 2026