Unified network of logistics facilities

Wireless infrastructure for ports, airports and terminals

We design wireless infrastructure for open areas, warehouses, gates, administrative zones and mobile terminal equipment. For each process, we determine the requirements for radio access and the backbone, and the result is checked by zone measurements and route tests.

Multilayer wireless infrastructure for a terminalA diagram of the backbone, Wi-Fi zones, warehouse, outdoor area, administrative area and mobile equipment.

Backbone → WLAN → mobile client → management → route test

Different zones of the terminal are united by a common architecture

Terminal wireless infrastructure connects outdoor areas, warehouses, gates, administrative spaces, and mobile equipment. WLANs, wireless and wired backbones, onboard clients, segmentation, and monitoring are designed together. Technologies are selected for each area and application.

Signs that a solution is needed

When fragmented infrastructure hinders the operation of the terminal

01

Outdoor areas lack connectivity

The warehouse has coverage, but the yard, apron, or quay has coverage gaps and unstable backhaul.

02

Equipment loses data

Cranes, forklifts and tractors interrupt telemetry when moving between zones.

03

Zones do not have a single management

Warehouse, gate, office and outdoor area use unrelated management schemes.

04

Redundancy is not coordinated

Failure of a backbone or node disrupts several technological processes.

Engineering constraints

Indoor and outdoor areas need different designs

01

Large area

Distances, terrain, buildings and machinery affect the placement of nodes and transport.

02

Mobile equipment

Routes, speed, antennas and onboard clients set a separate scenario.

03

Different applications

Handheld terminals, video, telemetry and control require different bandwidth and latency.

04

Complex installation

Masts, cranes, power, vibration, climate and access for maintenance are taken into account in advance.

05

Continuity

Redundancy is determined by the impact of a failure on a particular process.

Zones of the terminal

Each process receives a suitable radio layer.

01

Yard, apron and pier

Open coverage for equipment, employees, video and technology services.

02

Warehouse and gate

WMS, handheld terminals, printers, forklifts and control operations.

03

Cranes and container handling equipment

On-board terminals, telemetry and data transmission on a moving asset.

04

Administrative areas

Corporate and guest access with individual policies.

Multilayer architecture

From backbone links to onboard WLAN clients

01

Transport links between sites

PtP/PtMP wireless links, fiber, or hybrid connections between areas.

02

Wi‑Fi networks of individual zones

Access points and channel plan for warehouse, office and outdoor area.

03

Mobile clients

On-board units, antennas and routes of equipment.

04

Segmentation

Separation of technological, corporate, guest and video traffic.

05

Management and redundancy

Monitoring, configuration, events and recovery scenarios.

Selection by zone

One technology cannot serve the entire site

MechanismWhat it doesWhat we check
Centrally Managed WLANConnects standard Wi‑Fi clients in rooms and open areas, where applicability is confirmed by calculation and survey.Coverage, capacity, client devices, mobility, and mounting conditions.
Industrial meshMesh topology can be used in suitable distributed scenarios.Capacity per wireless hop, routing, resilience, and mobile client compatibility.
P2P/P2MPThe backbone between remote areas and sites.Path profile, frequency, bandwidth, and link margin.
Private LTE networkMay provide mobile radio access over a large site where spectrum and regulatory conditions permit.Frequencies, terminals, delay, integration, operation and economy.

Stages of the project

Assembling the terminal by zones and processes

  1. 01

    Document the task

    Define the site, applications, client devices, routes and result criteria.

  2. 02

    Check the initial conditions

    We study plans, existing infrastructure, RF environment and location restrictions.

  3. 03

    We design architecture

    Choose the technology, calculate the coverage and transport, form the scheme and specification.

  4. 04

    We deploy and configure

    Deploy multi-level terminal infrastructure, integrate management, policies and monitoring.

  5. 05

    We carry out acceptance

    We check the agreed zones, routes and applications, transfer protocols and documentation.

Results

Unified map of infrastructure

  • 01A map of areas, processes, applications, and client device classes
  • 02Backbone, radio access and redundancy diagram
  • 03Equipment routes and requirements for onboard units
  • 04Specification of equipment, installation and power supply
  • 05Zone and route test program

Acceptance

We test fixed zones and movement

CriterionHow to checkWhere we document
ZonesCoverage and load measurements according to the agreed map.Heat maps and protocol.
Routes of equipmentTest drives with an actual client and operational traffic profile.Route test logs and, with hardware support, connection or roaming events.
BackboneLoad test and verification of agreed failure scenarios.Link and failover test report.

Operation

Zones are managed as one infrastructure

01

Unified monitoring

Backbone, radio access, and mobile client status are visible in one monitoring environment.

02

Change procedures

New routes, equipment and construction are assessed by the impact on the radio network.

03

Timeframes

Depend on the availability of the source data, access to the facility, the composition of the infrastructure and the need for the pilot. Stages and control points are fixed before the start of work.

04

Cost

It is formed after clarifying the geography, application requirements, equipment composition, works and integrations. The estimates separate mandatory and optional parts.

05

Support and SLA

Support arrangements, response targets, monitoring, spare equipment, and escalation are agreed according to system criticality.

Questions and answers

Frequently asked questions about the solution

01Is it possible to cover the entire terminal with one type of access points?

Equipment cannot be selected from the terminal’s total area alone. Outdoor areas, warehouses, administrative buildings, and equipment routes differ in client devices, density, interference, mounting conditions, and application requirements. Each area receives a suitable RF design, coordinated within the overall architecture. Surveys, calculations, and agreed acceptance criteria determine the final equipment mix.

02How is port or airfield equipment connected?

The method depends on the equipment class and application and is selected after reviewing available onboard clients. Mounting location, antennas, power supply, vibration, speed, routes, and maintenance are assessed together with the RF layer. Suitability is confirmed only after testing target equipment or an agreed equivalent with documented settings and acceptance criteria.

03Do I need a separate backbone project?

The backbone forms part of the overall architecture. Whether a separate design is required depends on the existing infrastructure. We check routes, capacity, redundancy, power supply, and connection points, then determine whether the existing backbone is sufficient or a new design is needed. Fiber, PtP/PtMP, and other links are considered according to actual site conditions and verified suitability.

04When do you need an industrial mesh, and when do you need a regular WLAN?

Selection depends on topology, client mobility, the available backbone, permitted wireless hop count, capacity, and failure scenarios. A large area alone does not justify mesh, and WLAN is not limited to indoor use. We compare application requirements and operating conditions for each area, then validate the design through surveys, a pilot where needed, and agreed tests.

05Is it possible to upgrade infrastructure without stopping the terminal?

Modernization may be phased by area and service window, but continuity can be assessed only after reviewing the site and terminal processes. Before work begins, we document access restrictions, temporary switching, work at height, equipment access, and related system dependencies. Each stage includes verification, rollback procedures, and operational handover.

06How are climate and difficult installation conditions taken into account?

We collect conditions for each area: temperature, precipitation, wind, dust, possible salt spray, vibration, lightning protection, power supply, and maintenance access. These determine equipment, antenna, cable, and mount ratings and installation methods. Surveys and project documentation confirm requirements. Conditions in one area cannot automatically be applied across the whole terminal or another site.

07How are cranes, tractors and forklifts checked?

For each equipment class, we agree on the route, operating speed, onboard client, antenna, mounting location, and traffic profile. Tests record network metrics, connection events, and application behavior in representative areas. Results apply to the tested configuration and are included in the acceptance report with test conditions, criteria, and the equipment list.

08What data are needed for a preliminary assessment?

Provide a site plan and boundaries, areas and processes, equipment classes and routes, and applications with connectivity requirements. Include existing WLAN, fiber and radio links, power supply, mounting locations, access restrictions, and planned site changes. Missing inputs, survey needs, and file formats are clarified before a proposal is prepared.